Model

INV24E-005

INV24E-006

INV24E-015

Rated Power

625 VA

750 VA

1500 VA

Input

Voltage

20~30VDC

Output

Voltage

220VAC±2%

Frequency

50Hz

Waveform

Pure Sine Wave

Frequency Stability

<±0.1%

Crest Factor

>3:1

Harmonic Distortion

<3% THD for linear load

Voltage Transient (Step Load) Response

<±5% for 100% step load change

Voltage Recovery Time

Less than 10ms

Balance Load Voltage

<±1%, <±5% (non-balanced load voltage)

Inverter Efficiency

>90%

Overload Capability

120% for 1 minute

Ambient Temperature

-10~50°C

Cooling Style

Temperature operated force-cooled

Humidity

0-90% non-condensing

Audible Noise

<45dB

Protection Function

Short-circuit, Overload, Over-voltage, Under-voltage, Over-temperature

Weight

18kgs

Dimensions (L x W x H in mm)

500 x 162 x 327

Input/Output Layout

Receptacle

Indicators

Mains Supply (Green), Inverter (Green), Bypass Output (Orange), Battery Power (Red), Overload (Red), Malfunction (Red)

Model

INV48E-01RM

INV48E-02RM

INV48E-03RM

Rated Power

1kVA

2kVA

3kVA

Input

Voltage

48VDC±15%

Output

Voltage

220VAC±2%

Frequency

50Hz

Waveform

Pure Sine Wave

Frequency Stability

<±0.1%

Crest Factor

>3:1

Harmonic Distortion

<3% THD for linear load

Voltage Transient (Step Load) Response

<±5% for 100% step load change

Voltage Recovery Time

Less than 10ms

Balance Load Voltage

<±1%, <±5% (non-balanced load voltage)

Inverter Efficiency

>90%

Overload Capability

120% for 1 minute

Ambient Temperature

-10~50°C

Cooling Style

Temperature operated force-cooled

Humidity

0-90% non-condensing

Audible Noise

<45dB

Protection Function

Short-circuit, Overload, Over-voltage, Under-voltage, Over-temperature

Weight

67kgs

78kgs

Dimensions (L x W x H in mm)

340 x 480 x 865

Input/Output Layout

Terminals

Indicators

Mains Supply (Green), Inverter (Green), Bypass Output (Orange), Battery Power (Red), Overload (Red), Malfunction (Red)



Model

INV48E-01

INV48E-02

INV48E-025

INV48E-03

INV48E-035

INV48E-05

Rated Power

1 kVA

2 kVA

2.5 kVA

3 kVA

3.5 kVA

5 kVA

Input

Voltage

48VDC±15%

Output

Voltage

220VAC±1%

Frequency

50Hz

Waveform

Pure Sine Wave

Frequency Stability

<±0.1%

Crest Factor

>3:1

Harmonic Distortion

<3% THD for linear load

Voltage Transient (Step Load) Response

<±5% for 100% step load change

Voltage Recovery Time

Less than 10ms

Balance Load Voltage

<±1%, <±5% (non-balanced load voltage)

Inverter Efficiency

>90%

Overload Capability

120% for 1 minute

Ambient Temperature

-10~50°C

Cooling Style

Temperature operated force-cooled

Humidity

0-90% non-condensing

Audible Noise

<45dB

<50dB

Protection Function

Short-circuit, Overload, Over-voltage, Under-voltage, Over-temperature

Weight

67kgs

78kgs

95kgs

98kgs

152kgs

Dimensions (L x W x H in mm)

340 x 480 x 865

Input/Output Layout

Terminals

Indicators

Mains Supply (Green), Inverter (Green), Bypass Output (Orange), Battery Power (Red), Overload (Red), Malfunction (Red)

Model

INV110E-02

INV110E-03

INV110E-05

INV110E-06

INV110E-10

Rated Power

2 kVA

3 kVA

5 kVA

6 kVA

10 kVA

Input

Voltage

110VDC±15%

Output

Voltage

220VAC±1%

Frequency

50Hz

Waveform

Pure Sine Wave

Frequency Stability

<±0.1%

Crest Factor

>3:1

Harmonic Distortion

<3% THD for linear load

Voltage Transient (Step Load) Response

<±5% for 100% step load change

Voltage Recovery Time

Less than 10ms

Balance Load Voltage

<±1%, <±5% (non-balanced load voltage)

Inverter Efficiency

>90%

Overload Capability

120% for 1 minute

Ambient Temperature

-10~50°C

Cooling Style

Temperature operated force-cooled

Humidity

0-90% non-condensing

Audible Noise

<45dB

<50dB

Protection Function

Short-circuit, Overload, Over-voltage, Under-voltage, Over-temperature

Weight

67kgs

78kgs

95kgs

98kgs

152kgs

Dimensions (L x W x H in mm)

340 x 480 x 865

Input/Output Layout

Terminals

Indicators

Mains Supply (Green), Inverter (Green), Bypass Output (Orange), Battery Power (Red), Overload (Red), Malfunction (Red)

Model

INV220E-02

INV220E-03

INV220E-05

INV220E-06

Rated Power

2 kVA

3 kVA

5 kVA

6 kVA

Input

Voltage

220VDC±15%

Output

Voltage

220VAC±1%

 

Frequency

50Hz

 

Waveform

Pure Sine Wave

 

Frequency Stability

<±0.1%

 

Crest Factor

>3:1

 

Harmonic Distortion

<3% THD for linear load

Voltage Transient (Step Load) Response

<±5% for 100% step load change

Voltage Recovery Time

Less than 10ms

Balance Load Voltage

<±1%, <±5% (non-balanced load voltage)

Inverter Efficiency

>90%

Overload Capability

120% for 1 minute

Ambient Temperature

-10~50°C

Cooling Style

Temperature operated force-cooled

Humidity

0-90% non-condensing

Audible Noise

<45dB

Protection Function

Short-circuit, Overload, Over-voltage, Under-voltage, Over-temperature

Weight

67kgs

78kgs

95kgs

98kgs

Dimensions (L x W x H in mm)

340 x 480 x 865

Input/Output Layout

Terminals

Indicators

Mains Supply (Green), Inverter (Green), Bypass Output (Orange), Battery Power (Red), Overload (Red), Malfunction (Red)



Model

INV220E-10

INV220E-15

INV220E-20

Rated Power

10 kVA

15 kVA

20 kVA

Input

Voltage

220VDC±15%

Output

Voltage

220VAC±1%

 

Frequency

50Hz

 

Waveform

Pure Sine Wave

 

Frequency Stability

<±0.1%

 

Crest Factor

>3:1

 

Harmonic Distortion

<3% THD for linear load

Voltage Transient (Step Load) Response

<±5% for 100% step load change

Voltage Recovery Time

Less than 10ms

Balance Load Voltage

<±1%, <±5% (non-balanced load voltage)

Inverter Efficiency

>90%

Overload Capability

120% for 1 minute

Ambient Temperature

-10~50°C

Cooling Style

Temperature operated force-cooled

Humidity

0-90% non-condensing

Audible Noise

<50dB

Protection Function

Short-circuit, Overload, Over-voltage, Under-voltage, Over-temperature

Weight

152kgs

190kgs

240kgs

Dimensions (L x W x H in mm)

340 x 480 x 865

440 x 550 x 1070

Input/Output Layout

Terminals

Indicators

Mains Supply (Green), Inverter (Green), Bypass Output (Orange), Battery Power (Red), Overload (Red), Malfunction (Red)



Model

INV220T-10

INV220T-15

INV220T-20

INV220T-30

INV220T-40

INV220T-50

Rated Power

10 kVA

15 kVA

20 kVA

30 kVA

40 kVA

50 kVA

Input

Voltage

220VDC±15%

Output

Voltage

380VAC±1% 3-phase

Frequency

50Hz

Waveform

Pure Sine Wave

Frequency Stability

<±0.1%

Crest Factor

>3:1

Harmonic Distortion

<3% THD for linear load

Voltage Transient (Step Load) Response

<±5% for 100% step load change

Voltage Recovery Time

Less than 10ms

Balance Load Voltage

<±1%, <±5% (non-balanced load voltage)

Inverter Efficiency

>90%

Overload Capability

125% for 1 minute, 150% for 1 minute

Ambient Temperature

-10~50°C

Cooling Style

Temperature operated force-cooled

Humidity

0-90% non-condensing

Audible Noise

<50dB

<60dB

<68dB

Protection Function

Short-circuit, Overload, Over-voltage, Under-voltage, Over-temperature

Weight

128kgs

178kgs

260kgs

340kgs

380kgs

480kgs

Dimensions (L x W x H in mm)

340 x 480 x 865

440 x 550 x 1065

900 x 700 x 1400

Input/Output Layout

Terminals

Indicators

Mains Supply (Green), Inverter (Green), Bypass Output (Orange), Battery Power (Red), Overload (Red), Malfunction (Red)



Model

INV380T-10

INV380T-15

INV380T-20

INV380T-30

Rated Power

10 kVA

15 kVA

20 kVA

30 kVA

Input

Voltage

220VDC±15%

Output

Voltage

380VAC±1% 3-phase

 

Frequency

50Hz

 

Waveform

Pure Sine Wave

 

Frequency Stability

<±0.1%

 

Crest Factor

>3:1

 

Harmonic Distortion

<3% THD for linear load

Voltage Transient (Step Load) Response

<±5% for 100% step load change

Voltage Recovery Time

Less than 10ms

Balance Load Voltage

<±1%, <±5% (non-balanced load voltage)

Inverter Efficiency

>90%

Overload Capability

125% for 1 minute, 150% for 1 minute

Ambient Temperature

-10~50°C

Cooling Style

Temperature operated force-cooled

Humidity

0-90% non-condensing

Audible Noise

<50dB

<60dB

Protection Function

Short-circuit, Overload, Over-voltage, Under-voltage, Over-temperature

Weight

128kgs

178kgs

260kgs

340kgs

Dimensions (L x W x H in mm)

340 x 480 x 1065

440 x 550 x 1065

Input/Output Layout

Terminals

Indicators

Mains Supply (Green), Inverter (Green), Bypass Output (Orange), Battery Power (Red), Overload (Red), Malfunction (Red)



Model

INV380T-40

INV380T-50

INV380T-60

INV380T-80

Rated Power

40 kVA

50 kVA

60 kVA

80 kVA

Input

Voltage

220VDC±15%

Output

Voltage

380VAC±1% 3-phase

 

Frequency

50Hz

 

Waveform

Pure Sine Wave

 

Frequency Stability

<±0.1%

 

Crest Factor

>3:1

 

Harmonic Distortion

<3% THD for linear load

Voltage Transient (Step Load) Response

<±5% for 100% step load change

Voltage Recovery Time

Less than 10ms

Balance Load Voltage

<±1%, <±5% (non-balanced load voltage)

Inverter Efficiency

>90%

Overload Capability

125% for 1 minute, 150% for 1 minute

Ambient Temperature

-10~50°C

Cooling Style

Temperature operated force-cooled

Humidity

0-90% non-condensing

Audible Noise

<68dB

Protection Function

Short-circuit, Overload, Over-voltage, Under-voltage, Over-temperature

Weight

380kgs

480kgs

510kgs

800kgs

Dimensions (L x W x H in mm)

900 x 700 x 1400

800 x 900 x 1432

Input/Output Layout

Terminals

Indicators

Mains Supply (Green), Inverter (Green), Bypass Output (Orange), Battery Power (Red), Overload (Red), Malfunction (Red)